Diagnosis Procedure
- CHECK DOOR KEY CYLINDER SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect front door lock assembly LH connector.
- Check voltage between front door lock assembly LH harness connector and ground.
(+)
(-)
Voltage
(Approx.)
Front door lock assembly LH
Connector
Terminal
D10
5
Ground
5 V
6
Is the inspection result normal?
YES
GO TO 3 .
NO
GO TO 2 .
- CHECK DOOR KEY CYLINDER SWITCH SIGNAL CIRCUIT
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front door lock assembly LH harness connector.
Main power window and door lock/unlock switch
Front door lock assembly LH
Continuity
Connector
Terminal
Connector
Terminal
D7
3
D10
6
Yes
15
5
- Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch
Ground
Continuity
Connector
Terminal
D7
3
No
15
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK DOOR KEY CYLINDER SWITCH GROUND CIRCUIT
Check continuity between front door lock assembly LH harness connector and ground.
Front door lock assembly LH
Ground
Continuity
Connector
Terminal
D10
4
Yes
Is the inspection result normal?
YES
GO TO 4 .
NO
Repair or replace harness.
- CHECK DOOR KEY CYLINDER SWITCH
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 5 .
NO
Replace front door lock assembly LH. Refer to Removal and Installation .
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
Inspection End.