Diagnosis Procedure
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
- Disconnect EVAP control system pressure sensor harness connector.
- Check that water is not inside connectors.
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
+
-
Voltage (V)
EVAP control system pressure sensor
Connector
Terminal
B41
3
Ground
Approx. 5
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 3.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B41
3
E10
125
Existed
Is the inspection result normal?
YES
INSPECTION END
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B41
1
E10
148
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check EVAP control system pressure sensor. Refer to Component Inspection .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace EVAP control system pressure sensor. Refer to Removal and Installation .