LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 89 (Engine Control System (DTC/Circuit Diagnosis) (3 Of 5)) >> DTC/Circuit Diagnosis >> DTC P0452: EVAP Control System Pressure Sensor >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2018 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK CONNECTOR 
    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check that water is not inside connector.

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Repair or replace harness connector.

  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY 
    1. Turn ignition switch ON.
    2. Check the voltage between EVAP control system pressure sensor harness connector and ground.

      +

      -

      Voltage (V)

      EVAP control system pressure sensor

      Connector

      Terminal

      B41

      3

      Ground

      Approx. 5

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    GO TO 3.

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.

      EVAP control system pressure sensor

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      B41

      3

      E10

      125

      Existed

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Repair or replace harness connector.

  4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.

      EVAP control system pressure sensor

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      B41

      1

      E10

      148

      Existed

    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 5.

    NO

    Repair open circuit, short to ground or short to power in harness or connectors.

  5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT 
    1. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.

      EVAP control system pressure sensor

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      B41

      2

      E10

      121

      Existed

    2. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 6.

    NO

    Repair open circuit, short to ground or short to power in harness or connectors.

  6. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR 

    Check EVAP control system pressure sensor. Refer to Component Inspection .

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Replace EVAP control system pressure sensor. Refer to Removal and Installation .