Diagnosis Procedure
- PERFORM SELF DIAGNOSTIC RESULT
Perform "Self Diagnostic Result" of "IPDM E/R" using CONSULT.
Is display history of DTC B20A7 CRNT?
YES
GO TO 2 .
NO
Refer to Intermittent Incident .
- CHECK IGNITION SIGNAL CIRCUIT VOLTAGE
Check voltage between IPDM E/R connector E19 and ground.
IPDM E/R
Ground
Condition
Voltage
(Approx.)
Connector
Terminal
E19
43
-
Ignition switch: ON
0V
Ignition switch: OFF
Battery voltage
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to Removal and Installation .
NO
Voltage present with ignition switch OFF .
GO TO 3
NO
GO TO 4 .
- CHECK IGNITION SIGNAL CIRCUIT FOR SHORT TO VOLTAGE
- Disconnect IPDM E/R connector E19 and BCM connector M20.
- Check voltage between IPDM E/R connector E19 and ground.
IPDM E/R
Ground
Condition
Voltage
(Approx.)
Connector
Terminal
E19
43
-
Ignition switch: OFF
0V
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness or connectors.
- CHECK IGNITION SIGNAL CIRCUIT FOR OPEN OR SHORT TO GROUND
- Disconnect IPDM E/R connector E19 and BCM connector M20.
- Check continuity between IPDM E/R connector E19 and BCM connector M20.
IPDM E/R
BCM
Continuity
Connector
Terminal
Connector
Terminal
E19
43
M20
70
Yes
- Check continuity between IPDM E/R connector E19 and ground.
IPDM E/R
Ground
Continuity
Connector
Terminal
E19
43
-
No
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness or connectors.