Diagnosis Procedure
- CHECK BATTERY TERMINALS CONNECTION
Check if battery terminals are clean and tight.
Is the inspection result normal?
YES
GO TO 2 .
NO
Repair battery terminals connection. Confirm repair by performing system test using DSS-5000P NI. Refer to applicable Instruction Manual for proper testing procedures.
- CHECK FUSE
Check for blown fuse and fusible link.
Unit
Power source (Power supply terminals)
Fuse or Fusible Link No
Generator
Battery (terminal 3)
62 (10 A)
Battery (terminal 1)
Fusible Link A (250 A)
Combination meter
Ignition switch ON or START (terminal 2)
31 (5 A)
Is the inspection result normal?
YES
GO TO 3 .
NO
Replace the blown fuse or fusible link after repairing the affected circuit.
- CHECK DRIVE BELT TENSION
Check drive belt tension. Refer to Check Drive Belt .
Is the inspection result normal?
YES
Inspection End.
NO
Repair as needed.