Diagnosis Procedure
- CHECK OUTPUT 1 - 5 SYSTEM CIRCUIT FOR OPEN
- Turn the ignition switch OFF.
- Disconnect BCM connector M21 and combination switch connector M28.
- Check continuity between BCM harness connector M21 and combination switch harness connector M28.
Combination switch signal
BCM
Combination switch
Continuity
Connector
Terminal
Connector
Terminal
OUTPUT 1
M21
14
M28
12
Yes
OUTPUT 2
13
14
OUTPUT 3
12
5
OUTPUT 4
11
2
OUTPUT 5
10
8
Is the inspection result normal?
YES
GO TO 2 .
NO
Repair or replace harness.
- CHECK OUTPUT 1 - 5 SYSTEM CIRCUIT FOR SHORT
Check for continuity between BCM harness connector M21 and ground.
Combination switch signal
BCM
Ground
Continuity
Connector
Terminal
OUTPUT 1
M21
14
No
OUTPUT 2
13
OUTPUT 3
12
OUTPUT 4
11
OUTPUT 5
10
Is the inspection result normal?
YES
GO TO 3 .
NO
Repair or replace harness.
- CHECK BCM INPUT VOLTAGE
- Connect BCM connector M21 and combination switch connector M28.
- Turn ignition switch ON.
- Check voltage between BCM harness connector M21 and ground.
Combination switch signal
Terminals
Voltage
(Approx.)
(+)
(-)
BCM
Ground
Connector
Terminal
OUTPUT 1
M21
14
Refer to Reference Value .
OUTPUT 2
13
OUTPUT 3
12
OUTPUT 4
11
OUTPUT 5
10
Is the measurement normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Replace the combination switch. Refer to Removal and Installation .