Exterior Lighting System (Circuit Diagnosis)
- CHECK HAZARD SWITCH SIGNAL INPUT
- Turn the ignition switch OFF.
- Disconnect multifunction switch harness connector.
- Turn the ignition switch ON.
- Check voltage between multifunction switch harness connector and ground.
(+)
(-)
Voltage
(Approx.)
Multifunction switch (hazard switch)
Connector
Terminal
M98
16
Ground
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 2.
- CHECK HAZARD SWITCH SIGNAL OPEN CIRCUIT
- Turn the ignition switch OFF.
- Disconnect BCM harness connector M18.
- Check continuity between multifunction switch harness connector and BCM harness connector.
Hazard switch
BCM
Continuity
Connector
Terminal
Connector
Terminal
M98
16
M18
36
Yes
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace the harness or connectors.
- CHECK HAZARD SWITCH SIGNAL SHORT CIRCUIT
Check continuity between multifunction switch harness connector and ground.
Hazard switch
Ground
Continuity
Connector
Terminal
M98
16
No
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace the harness or connectors.
- CHECK HAZARD SWITCH GROUND OPEN CIRCUIT
Check continuity between multifunction switch harness connector and ground.
Hazard switch
Ground
Continuity
Connector
Terminal
M98
1
Yes
Is the inspection result normal?
YES
Replace multifunction switch. Refer to Removal and Installation .
NO
Repair or replace the harness or connectors.