Exterior Lighting System (Circuit Diagnosis)
- CHECK DAYTIME RUNNING LIGHT RELAY VOLTAGE SUPPLY
- Turn the ignition switch OFF.
- Disconnect the daytime running light relay harness connector.
- Turn the ignition switch ON.
- Check the voltage between the following daytime running light relay harness connector terminals and ground.
(+)
(-)
Voltage
Connector
Terminal
E4
2
Ground
Battery voltage
5
7
Is the inspection results normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK DAYTIME RUNNING LIGHT RELAY CIRCUIT
- Turn the ignition switch OFF.
- Disconnect IPDM E/R harness connector E121.
- Disconnect daytime running light relay harness connector.
- Check continuity between the IPDM E/R harness connector and the daytime running light relay harness connector.
Daytime running light relay
IPDM E/R
Continuity
Connector
Terminal
Connector
Terminal
E4
2
E121
14
Yes
5
7
- Check continuity between the IPDM E/R harness connector and ground.
Connector
Terminal
(--)
Continuity
E121
14
Ground
No
Is the inspection results normal?
YES
Replace IPDM E/R. Refer to Removal and Installation .
NO
Repair or replace the harnesses or connectors.
- CHECK DAYTIME RUNNING LAMP RELAY COIL CIRCUIT
- Check continuity between the IPDM E/R harness connector and daytime running light relay harness connector.
IPDM E/R
Daytime running light relay
Continuity
Connector
Terminal
Connector
Terminal
E218
85
E4
1
Yes
- Check continuity between the IPDM E/R harness connector E218 and ground.
Connector
Terminal
Ground
Continuity
E218
85
No
Is the inspection results normal?
YES
GO TO 4.
NO
Repair or replace the harnesses or connectors.
- Check continuity between the IPDM E/R harness connector and daytime running light relay harness connector.
- CHECK DAYTIME RUNNING LIGHT RELAY
Check the daytime running light relay. Refer to Component Inspection .
Is the inspection results normal?
YES
GO TO 5.
NO
Replace relay.
- CHECK DAYTIME RUNNING LAMP CIRCUIT FOR OPEN
- Turn the ignition switch OFF.
- Disconnect the front combination lamp harness connector E233 or E238 in question.
- Check continuity between the daytime running light relay harness connector and the front combination lamp harness connector.
Front combination lamp
Daytime running light relay
Continuity
Connector
Terminal
Connector
Terminal
LH
E233
7
E4
6
Yes
RH
E238
3
Is the inspection results normal?
YES
GO TO 6.
NO
Repair or replace the harnesses or connectors.
- CHECK DAYTIME RUNNING LAMP GROUND CIRCUIT FOR OPEN
Check continuity between the front combination lamp harness connector and ground.
Connector
Terminal
(-)
Continuity
LH
E233
3
Ground
Yes
RH
E238
Does continuity exist?
YES
Inspection End.