Diagnosis Procedure
WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK SECURITY INDICATOR LAMP POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector and ground.
(+)
(-)
Voltage (V)
Combination meter
Connector
Terminal
M24
22
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 2.
NO
Check 10 A fuse [No. 13, located in the fuse block (J/B)].
NO
Check harness for open or short between combination meter and fuse.
- CHECK SECURITY INDICATOR LAMP SIGNAL
- Connect combination meter connector.
- Disconnect BCM connector.
- Check voltage between BCM harness connector and ground.
(+)
(-)
Voltage (V)
BCM
Connector
Terminal
M18
18
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 4.
- REPLACE BCM
- Replace BCM. Refer to Removal and Installation .
- Perform initialization of BCM and registration of all Intelligent Keys using CONSULT.
Inspection End.
- CHECK SECURITY INDICATOR LAMP CIRCUIT
- Disconnect combination meter connector.
- Check continuity between combination meter harness connector and BCM harness connector.
Combination meter
BCM
Continuity
Connector
Terminal
Connector
Terminal
M24
6
M18
18
Yes
- Check continuity between combination meter harness connector and ground.
Combination meter
Ground
Continuity
Connector
Terminal
M24
6
No
Is the inspection result normal?
YES
Replace combination meter. Refer to Removal and Installation .
NO
Repair or replace harness.