Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E9. Refer to Ground Inspection in Circuit Inspection .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace ground connection.
- CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY
- Disconnect A/F sensor 1 harness connector.
- Turn ignition switch ON.
- Check the voltage between A/F sensor 1 harness connector and ground.
DTC
+
-
Voltage
A/F sensor 1
Bank
Connector
Terminal
P2241
2
F73
1
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 3.
- CHECK A/F SENSOR 1 POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and A/F sensor 1 harness connector.
DTC
IPDM E/R
A/F sensor 1
Continuity
Connector
Terminal
Connector
Terminal
P2241
F19
53
F73
1
Existed
- Also check harness for short to ground.
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between A/F sensor 1 harness connector and ECM harness connector.
DTC
A/F sensor 1
ECM
Continuity
Bank
Connector
Terminal
Connector
Terminal
P2241
2
F73
3
F79
111
Existed
4
107
- Check the continuity between A/F sensor 1 harness connector and ground, or ECM harness connector and ground.
DTC
A/F sensor 1
--
Continuity
Bank
Connector
Terminal
P2241
2
F73
3
Ground
Not existed
4
DTC
ECM
--
Continuity
Bank
Connector
Terminal
P2241
2
F79
111
Ground
Not existed
107
- Also check harness for short to power.
Is the inspection result normal?
YES
Replace malfunctioning air fuel ratio (A/F) sensor 1. Refer to AIR CLEANER AND AIR DUCT .
NO
Repair open circuit, short to ground or short to power in harness or connectors.