LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 673 (Interior Lighting System (Circuit Diagnosis)) >> Circuit Diagnosis >> Interior Room Lamp Control Circuit >> Diagnosis Procedure >> Interior Lighting System (Circuit Diagnosis)

Interior Lighting System (Circuit Diagnosis)

WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK INTERIOR ROOM LAMP CONTROL OUTPUT 

    SYMBOL CONSULT

    1. Turn ignition switch ON.
    2. Select INT LAMP of BCM (INT LAMP) active test item.
    3. While operating the test item, check voltage between BCM harness connector M81 terminal 136 and ground.

    BCM

    Ground

    Test item

    Voltage

    (Approx.)

    Connector

    Terminal

    M81

    136

    INT LAMP

    On

    0 V

    Off

    Battery voltage

    Is the inspection result normal?

    YES

    Interior room lamp control circuit is operating normally.

    Fixed ON

    GO TO 3.

    Fixed OFF

    GO TO 2.

  2. CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect BCM harness connector M81, front room/map lamp assembly harness connector R107 and cargo lamp harness connector R104.
    3. Check continuity between BCM harness connector M81 terminal 136 and front room/map lamp assembly harness connector R107 terminal 7 and cargo lamp harness connector R104 terminal 3.

      BCM

      Foot lamp

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      M81

      136

      Front room/map lamp assembly

      R107

      7

      Yes

      Cargo lamp

      R104

      3

    4. Reconnect the front room/map lamp assembly harness connector.
    5. Check continuity between BCM harness connector M81 terminal 136 and personal lamps 2nd row harness connector R106 terminal 3.

      BCM

      Personal lamps 2nd row

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      M81

      136

      R106

      3

      Yes

    Is the inspection result normal?

    YES

    Check interior room lamps for an open. If NG, replace lamp in question. Refer to Removal and Installation (Front room/map lamp), Removal and Installation (Cargo lamp) or Removal and Installation (Personal lamps 2nd row). If OK, replace BCM. Refer to Removal and Installation .

    NO

    Repair or replace harness or connectors.

  3. CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect BCM harness connector M81, front room/map lamp assembly harness connector R107 and cargo lamp harness connector R104.
    3. Check continuity between BCM harness connector M81 terminal 136 and ground.

      BCM

      Ground

      Continuity

      Connector

      Terminal

      M81

      136

      No

    Is the inspection result normal?

    YES

    Check interior room lamps for a short circuit. If NG, replace lamp in question. Refer to Removal and Installation (Front room/map lamp), Removal and Installation (Cargo lamp) or Removal and Installation (Personal lamps 2nd row). If OK, replace BCM. Refer to Removal and Installation .

    NO

    Repair or replace harness or connectors.