Diagnosis Procedure
- CHECK MICROPHONE SIGNAL
- Turn ignition switch ON.
- Check the signal between the terminals of AV control unit connector M161.
AV control unit connector M161
Condition
Reference value
(+)
(-)
Terminal
46
48
Speak into microphone.
Is the inspection result normal?
YES
Replace AV control unit. Refer to Removal and Installation .
NO
GO TO 2 .
- CHECK VOLTAGE MICROPHONE VCC
- Turn ignition switch OFF.
- Disconnect microphone connector.
- Turn ignition switch ON.
- Check the voltage between the terminals of microphone connector R22.
Microphone connector R22
Voltage
(Approx.)
(+)
(-)
Terminal
4
2
5.0 V
Is the inspection result normal?
YES
Replace microphone. Refer to Removal and Installation .
NO
GO TO 3 .
- CHECK MICROPHONE CIRCUIT FOR OPEN
- Turn ignition switch OFF.
- Disconnect AV control unit connector M161.
- Check continuity between AV control unit connector M161 and microphone connector R22.
AV control unit
Microphone
Continuity
Connector
Terminal
Connector
Terminal
M161
46
R22
1
Yes
47
4
48
2
Is the inspection result normal?
YES
GO TO 4 .
NO
Repair or replace harness or connectors.
- CHECK MICROPHONE CIRCUIT FOR SHORT
Check the continuity between AV control unit connector M161 and ground.
(+)
(-)
Continuity
AV control unit
Connector
Terminal
M161
46
Ground
No
47
Is the inspection result normal?
YES
Replace AV control unit. Refer to Removal and Installation .
NO
Repair or replace harness or connectors.