Diagnosis Procedure
- CHECK MOTOR SENSOR (RH) POWER SUPPLY
- Turn the ignition switch OFF.
- Disconnect power return motor assembly (RH) connector.
- Check voltage between power return motor assembly (RH) harness connector and ground.
(+)
(-)
Condition
Voltage (V)
Power return motor assembly (RH)
Connector
Terminal
B417
2
Ground
When power return motor (RH) is operated
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK MOTOR SENSOR (RH) POWER SUPPLY CIRCUIT
- Disconnect seatback power return control unit connector B412.
- Check continuity between seatback power return control unit harness connector and power return motor assembly (RH) harness connector.
Seatback power return control unit
Power return motor assembly (RH)
Continuity
Connector
Terminal
Connector
Terminal
B412
1
B417
2
Yes
- Check continuity between seatback power return control unit harness connector and ground.
Seatback power return control unit
Ground
Continuity
Connector
Terminal
B412
1
No
Is the inspection result normal?
YES
Replace seatback power return control unit. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK MOTOR SENSOR (RH) GROUND CIRCUIT
- Check continuity between seatback power return control unit harness connector and power return motor assembly (RH) harness connector.
Seatback power return control unit
Power return motor assembly (RH)
Continuity
Connector
Terminal
Connector
Terminal
B412
8
B417
5
Yes
- Check continuity between seatback power return control unit harness connector and ground.
Seatback power return control unit
Ground
Continuity
Connector
B412
8
No
Is the inspection result normal?
YES
GO TO 4.
NO
Repair or replace harness.
- Check continuity between seatback power return control unit harness connector and power return motor assembly (RH) harness connector.
- CHECK MOTOR SENSOR (RH) OUTPUT SIGNAL
- Connect seatback power return control unit connector B412.
- Check signal between seatback power return control unit harness connector and ground with an oscilloscope.
(+)
(-)
Condition
Signal
(Reference value)
Seatback power return control unit
Connector
Terminal
B412
7
Ground
During the power return motor (RH) operation
When pinching seatback occurs
The above pulse width should be expanded
Is the inspection result normal?
YES
GO TO 6.
NO
GO TO 5.
- CHECK MOTOR SENSOR (RH) SIGNAL CIRCUIT
- Disconnect power return motor assembly (RH) connector and seatback power return control unit connector B412.
- Check continuity between power return motor assembly (RH) harness connector and seatback power return control unit harness connector.
Seatback power return control unit
Power return motor assembly (RH)
Continuity
Connector
Terminal
Connector
Terminal
B412
7
B417
4
Yes
- Check continuity between seatback power return control unit harness connector and ground.
Seatback power return control unit
Ground
Continuity
Connector
Terminal
B412
7
No
Is the inspection result normal?
YES
Replace power return motor assembly (RH). Refer to Exploded View .
NO
Repair or replace harness.
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
Inspection End.