LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 648 (Engine Control System (DTC/Circuit Diagnosis) (2 Of 17)) >> DTC/Circuit Diagnosis >> DTC P0057: Ho2S2 Heater >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK HEATED OXYGEN SENSOR 2 HEATER POWER SUPPLY CIRCUIT-I 
    1. Turn ignition switch OFF.
    2. Disconnect heated oxygen sensor 2 harness connector.
    3. Turn ignition switch ON.
    4. Check the voltage between heated oxygen sensor 2 harness connector and ground.

      DTC

      +

      -

      Voltage

      Heated oxygen sensor 2

      Bank

      Connector

      Terminal

      P0037, P0038

      1

      F71 *1

      F82 *2

      1

      Ground

      Battery voltage

      P0057, P0058

      2

      F70 *1

      F81 *2

      1

      *1 : With black connector

      *2 : With gray connector

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    GO TO 4.

  2. CHECK HEATED OXYGEN SENSOR 2 HEATER OUTPUT SIGNAL CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between heated oxygen sensor 2 harness connector and ECM harness connector.

      DTC

      Heated oxygen sensor 2

      ECM

      Continuity

      Bank

      Connector

      Terminal

      Connector

      Terminal

      P0037, P0038

      1

      F71 *1

      F82 *2

      2

      F79

      166

      Existed

      P0057, P0058

      2

      F70 *1

      F81 *2

      2

      163

      *1 : With black connector

      *2 : With gray connector

    4. Also check harness for short to power and short to ground.

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair open circuit, short to ground or short to power in harness or connectors.

  3. CHECK HEATED OXYGEN SENSOR 2 HEATER 

    Check heated oxygen sensor 2 heater. Refer to Component Inspection (Heated Oxygen Sensor 2 Heater) .

    Is the inspection result normal?

    YES

    INSPECTION END.

    NO

    Replace malfunctioning heated oxygen sensor 2. Refer to EXHAUST MANIFOLD AND THREE WAY CATALYST .

  4. CHECK HEATED OXYGEN SENSOR 2 HEATER POWER SUPPLY CIRCUIT-II 
    1. Turn ignition switch OFF.
    2. Disconnect IPDM E/R harness connector.
    3. Check the continuity between IPDM E/R harness connector and heated oxygen sensor 2 harness connector.

      DTC

      IPDM E/R

      Heated oxygen sensor 2

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      P0037, P0038

      F19

      52

      F71 *1

      F82 *2

      1

      Existed

      P0057, P0058

      F70 *1

      F81 *2

      1

      *1 : With black connector

      *2 : With gray connector

    4. Also check harness for short to ground.

    Is the inspection result normal?

    YES

    Perform the trouble diagnosis for power supply circuit.

    NO

    Repair or replace error-detected parts.