Diagnosis Procedure
- CHECK AV COMMUNICATION LOW CIRCUIT CONTINUITY
- Turn ignition switch OFF.
- Disconnect AV control unit connector M163, data link connector, combination meter connector M23, multifunction switch connector and Bose speaker amp. connector B149.
- Check continuity between AV control unit connector M163 and data link connector M22.
AV control unit
Data link
Continuity
Connector
Terminal
Connector
Terminal
M163
23
M22
3
Yes
- Check continuity between AV control unit connector M163 and combination meter connector M23.
AV control unit
Combination meter
Continuity
Connector
Terminal
Connector
Terminal
M163
23
M23
49
Yes
- Check continuity between AV control unit connector M163 and multifunction switch connector M259.
AV control unit
Multifunction switch
Continuity
Connector
Terminal
Connector
Terminal
M163
23
M259
4
Yes
- Check continuity between AV control unit connector M163 and Bose speaker amp. connector B149.
AV control unit
Bose speaker amp.
Continuity
Connector
Terminal
Connector
Terminal
M163
23
B149
51
Yes
21
52
- Check continuity between AV control unit connector M163 and ground.
AV control unit
Ground
Continuity
Connector
Terminal
M163
23
-
No
21
Is the inspection result normal?
YES
GO TO 2
NO
Repair or replace harness or connectors.
- CHECK AV COMMUNICATION HIGH CIRCUIT CONTINUITY
- Check continuity between AV control unit connector M163 and data link connector M22.
AV control unit
Data link
Continuity
Connector
Terminal
Connector
Terminal
M163
24
M22
11
Yes
- Check continuity between AV control unit connector M163 and combination meter connector M23.
AV control unit
Combination meter
Continuity
Connector
Terminal
Connector
Terminal
M163
24
M23
50
Yes
- Check continuity between AV control unit connector M163 and multifunction switch connector M259.
AV control unit
Multifunction switch
Continuity
Connector
Terminal
Connector
Terminal
M163
24
M259
3
Yes
- Check continuity between AV control unit connector M163 and Bose speaker amp. connector B149.
AV control unit
Bose speaker amp.
Continuity
Connector
Terminal
Connector
Terminal
M163
24
B149
71
Yes
22
72
- Check continuity between AV control unit connector M163 and ground.
AV control unit
Ground
Continuity
Connector
Terminal
M163
24
-
No
22
Is the inspection result normal?
YES
Replace the AV control unit. Refer to Removal and Installation .
NO
Repair or replace harness or connectors.
- Check continuity between AV control unit connector M163 and data link connector M22.