LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 635 (ADAS Control Unit (DTC/Circuit Diagnosis)) >> DTC/Circuit Diagnosis >> Power Supply And Ground Circuit >> ADAS Control Unit 2 >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK FUSE 

    Check that the following fuse is not blown:

    Signal name

    Fuse No.

    Ignition power supply

    30 (10A)

    Is the fuse blown?

    YES

    Replace the blown fuse after repairing the affected circuit.

    NO

    GO TO 2.

  2. CHECK ADAS CONTROL UNIT 2 POWER SUPPLY CIRCUIT 

    Check voltage between ADAS control unit 2 harness connector and ground.

    Terminal

    Condition

    Voltage

    (Approx.)

    (+)

    (-)

    ADAS control unit 2

    Ground

    Ignition switch

    Connector

    Terminal

    M198

    3

    OFF

    0 V

    ON

    Battery voltage

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair the ADAS control unit 2 power supply circuit.

  3. CHECK ADAS CONTROL UNIT 2 GROUND CIRCUIT 
    1. Turn the ignition switch OFF.
    2. Disconnect the ADAS control unit 2.
    3. Check for continuity between ADAS control unit 2 harness connector and ground.

      ADAS control unit 2

      Ground

      Continuity

      Connector

      Terminal

      M198

      1

      Yes

    Is the inspection result normal?

    YES

    Inspection End.

    NO

    Repair the ADAS control unit 2 ground circuit.