Diagnosis Procedure
WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect auto anti-dazzling inside mirror (homelink ® universal transceiver) connector.
- Check voltage between auto anti-dazzling inside mirror (homelink ® universal transceiver) harness connector and ground.
Auto anti-dazzling inside mirror
(Homelink ® universal transceiver) connector
Terminal
Condition
Voltage (V)
(Approx.)
R10
10
Ground
Ignition switch position: OFF
Battery voltage
Ignition switch position: ON
6
Ignition switch position: OFF
0
Ignition switch position: ON
Battery voltage
Is the inspection result normal?
YES
GO TO 2.
NO
Check the following items.
- 5A fuse [No. 29 located in the fuse block (J/B)]
- 10A fuse [No. 1 located in the fuse block (J/B)]
- Harness for open or short between fuse and auto anti-dazzling inside mirror (homelink ® universal transceiver).
- CHECK GROUND CIRCUIT
Check continuity between auto anti-dazzling inside mirror (homelink ® universal transceiver) harness connector and ground.
Auto anti-dazzling inside mirror
(Homelink ® universal transceiver) connector
Terminal
Ground
Continuity
R10
8
Yes
Is the inspection result normal?
YES
GO TO 3.
NO
Repair harness.
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
Inspection End.