LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 628 (Door & Lock (DTC/Circuit Diagnosis)) >> DTC/Circuit Diagnosis >> Fuel Lid Lock Actuator >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK FUEL LID DOOR LOCK ACTUATOR INPUT SIGNAL 
    1. Turn ignition switch OFF.
    2. Disconnect fuel lid door lock actuator connector.
    3. Check voltage between fuel lid door lock actuator harness connector and ground.

      (+)

      (-)

      Condition

      Voltage

      (Approx.)

      Fuel lid door lock actuator

      Connector

      Terminal

      B20

      1

      Ground

      Door lock and unlock switch

      Unlock

      Battery voltage

      2

      Lock

    Is the inspection result normal?

    YES

    Replace fuel lid door lock actuator. Refer to Removal and Installation .

    NO

    GO TO 2.

  2. CHECK FUEL LID DOOR LOCK ACTUATOR CIRCUIT 
    1. Disconnect BCM and all door lock actuators connector.
    2. Check continuity between BCM harness connector and fuel lid door lock actuator harness connector.

      BCM

      Fuel lid door lock actuator

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      M81

      135

      B20

      2

      Yes

      137

      1

    3. Check continuity between BCM harness connector and ground.

      BCM

      Ground

      Continuity

      Connector

      Terminal

      M81

      135

      No

      137

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair or replace harness.

  3. CHECK BCM OUTPUT SIGNAL 
    1. Connect BCM connector.
    2. Check voltage between BCM harness connector and ground.

    (+)

    (-)

    Condition

    Voltage

    (Approx.)

    BCM

    Connector

    Terminal

    M81

    135

    Ground

    Door lock and unlock switch

    Lock

    Battery voltage

    137

    Unlock

    Is the inspection result normal?

    YES

    Check for internal short of each door lock actuator.

    NO

    Replace BCM. Refer to Removal and Installation .