Diagnosis Procedure
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect automatic back door close switch connector.
- Check voltage between automatic back door close switch harness connector and ground.
(+)
(-)
Voltage
(Approx.)
Automatic back door close switch
Connector
Terminal
D560
1
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH CIRCUIT
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and automatic back door close switch harness connector.
Automatic back door control module
Automatic back door close switch
Continuity
Connector
Terminal
Connector
Terminal
B55
23
D560
1
Yes
- Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module
Ground
Continuity
Connector
Terminal
B55
23
No
Is the inspection result normal?
YES
Replace automatic back door control module. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH GROUND CIRCUIT
Check continuity between automatic back door close switch harness connector and ground.
Automatic back door close switch
Ground
Continuity
Connector
Terminal
D560
2
Yes
Is the inspection result normal?
YES
GO TO 4.
NO
Repair or replace harness.
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 5.
NO
Replace automatic back door close switch. Refer to Removal and Installation .
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
Inspection End.