Diagnosis Procedure
- CHECK IGNITION RELAY-2 SUPPLY VOLTAGE
- Disconnect ignition relay-2.
- Check voltage between ignition relay-2 connector and ground.
Ignition relay-2
Ground
Condition
Voltage
(Approx.)
Connector
Terminal
J-1
3
w
Ignition: OFF
Battery voltage
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace harness or connectors.
- CHECK IGNITION RELAY-2 CONTROL SIGNAL VOLTAGE
Check voltage between ignition relay-2 connector and ground.
Ignition relay-2
Ground
Condition
Voltage
(Approx.)
Connector
Terminal
J-1
1
--
Ignition: OFF
0V
Ignition: ON
Battery voltage
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 3.
- CHECK IGNITION RELAY-2 CONTROL SIGNAL CIRCUIT
- Turn the push-button ignition switch OFF.
- Disconnect BCM connector M19.
- Check continuity between BCM connector and ignition relay-2 connector.
BCM
Ignition relay-2
Continuity
Connector
Terminal
Connector
Terminal
M19
67
J-1
1
Yes
- Check continuity between BCM connector and ground.
BCM
Ground
Continuity
Connector
Terminal
M19
67
--
No
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness or connectors.
- CHECK IGNITION RELAY-2 GROUND CIRCUIT
- Turn the push-button ignition switch OFF.
- Check continuity between ignition relay-2 connector and ground.
Ignition relay-2
Ground
Continuity
Connector
Terminal
J-1
2
--
Yes
Is the inspection result normal?
YES
Replace ignition relay-2.
NO
Repair or replace harness or connectors.