Diagnosis Procedure
- CHECK STOP LAMP SWITCH CIRCUIT
- Turn ignition switch OFF.
- Check the stop lamp when depressing and releasing the brake pedal.
Brake pedal
Stop lamp
Fully released
Not illuminated
Slightly depressed
Illuminated
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 2.
- CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
- Disconnect stop lamp switch harness connector.
- Check the voltage between stop lamp switch harness connector and ground.
+
-
Voltage
Stop lamp switch
Connector
Terminal
E38
3
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 3.
- CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect fuse block (J/B) harness connector.
- Check the continuity between brake pedal position switch harness connector and fuse block (J/B) harness connector.
Stop lamp switch
Fuse block (J/B)
Continuity
Connector
Terminal
Connector
Terminal
E38
3
E28
5M
Existed
- Also check harness for short to ground.
Is the inspection result normal?
YES
GO TO 4.
NO
Repair or replace error-detected parts.
- CHECK FUSE
Check that the following fuse is not blowing.
Location
Fuse No.
Capacity
Fuse block (J/B)
#10
10A
Is the fuse blown (open)?
YES
Replace the fuse after repairing the applicable circuit.
NO
Perform trouble diagnosis for power supply circuit.
- CHECK STOP LAMP SWITCH INPUT SIGNAL CIRCUIT
- Disconnect stop lamp switch harness connector.
- Disconnect ECM harness connector.
- Check the continuity between stop lamp switch harness connector and ECM harness connector.
Stop lamp switch
ECM
Continuity
Connector
Terminal
Connector
Terminal
E38
4
E32
191
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace error-detected parts.
- CHECK STOP LAMP SWITCH
Refer to Component Inspection (Stop Lamp Switch) .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace stop lamp switch. Refer to Exploded View .