Component Inspection
WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK VIAS CONTROL SOLENOID VALVE 2
With CONSULT
- Turn ignition switch OFF.
- Reconnect all harness connectors disconnected.
- Disconnect vacuum hoses connected to VIAS control solenoid valve 2.
- Turn ignition switch ON.
- On CONSULT screen, select "ENGINE">>"Active Test">>"VIAS S/V-2"".
- Check air passage continuity and operation delay time under the following conditions.
Condition
(VIAS S/V-2)
Air passage continuity between
and
Air passage continuity
between
and
ON
Existed
Not existed
OFF
Not existed
Existed
Without CONSULT
- Turn ignition switch OFF.
- Disconnect VIAS control solenoid valve 2 harness connector.
- Disconnect vacuum hoses connected to VIAS volume control solenoid valve 2.
- Check air passage continuity and operation delay time under the following conditions.
Condition
Air passage continuity between
and
Air passage continuity
between
and
12 V direct current supply between terminals 1 and 2
Existed
Not existed
No supply
Not existed
Existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace VIAS control solenoid valve 2. Refer to INTAKE MANIFOLD COLLECTOR .