  1. Install the studs in the exhaust manifold (if removed), and tighten to specification.

    Exhaust manifold studs

    : 15.4 N.m (1.6 kg-m, 11 ft-lb)

  2. Install the exhaust manifold gasket in the direction shown, below.
    G00465472Courtesy of NISSAN NORTH AMERICA, INC.
    CAUTION: Do not reuse gasket.

    (A)

    : Bank 1

    (B)

    : Triangle press

    (C)

    : Bank 2

    SYMBOL

    : Engine front

  3. Install the exhaust manifold (bank 1) nuts and tighten to the specified torque in the sequence shown, below.
    Fig 1: Exhaust Manifold (Bank 1) Nut Tightening Sequence
    G08768763Courtesy of NISSAN NORTH AMERICA, INC.
    NOTE: Number 7 and 8 are tightened a second time.

    Exhaust manifold (bank 1) bolts

    : 30.9 N.m (3.2 kg-m, 23 ft-lb)

    SYMBOL

    : Engine front

  4. Install exhaust manifold cover (bank 1) and tighten bolts to the specified torque in the sequence shown, below.
    Fig 2: Exhaust Manifold Cover (Bank 1) Bolt Tightening Sequence
    GNSALBIA3199Z-199Courtesy of NISSAN NORTH AMERICA, INC.

    Exhaust manifold cover (bank 1) bolts

    : 5.8 N.m (0.59 kg-m, 51 in-lb)

  5. Installation of the remaining components is in the reverse order of removal.
    CAUTION:
    • Before installing a heated oxygen sensor or air fuel ratio (A/F) sensor, clean the exhaust manifold threads using the oxygen sensor thread cleaner tool and apply anti-seize lubricant.

      Oxygen sensor thread cleaner

      :--(J-43897-18)

      Oxygen sensor thread cleaner

      :--(J-43897-12)

    • Do not over-tighten the air fuel ratio (A/F) sensor or heated oxygen sensors. Doing so may cause damage.

      Tool numbers

      : KV10114400 (J-38365)