Data Monitor
|
Monitor item [Unit] |
Description |
|
|
AMB TEMP SEN |
[ deg.C (deg.F)] |
Ambient sensor value converted from ambient sensor signal received from ambient sensor. |
|
IN-VEH TEMP |
[ deg.C (deg.F)] |
In-vehicle sensor value converted from in-vehicle sensor signal received from in-vehicle sensor. |
|
INT TEMP SEN |
[ deg.C (deg.F)] |
Intake sensor value converted from intake sensor signal received from intake sensor. |
|
SUNLOAD SEN |
[w/m 2 ] |
Sunload sensor value converted from sunload sensor signal received from sunload sensor. |
|
AMB SEN CAL |
[ deg.C (deg.F)] |
Ambient temperature value calculated by A/C auto amp. |
|
IN-VEH CAL |
[ deg.C (deg.F)] |
In-vehicle temperature value calculated by A/C auto amp. |
|
INT TEMP CAL |
[ deg.C (deg.F)] |
Front evaporator fin temperature value calculated by A/C auto amp. |
|
SUNL SEN CAL |
[w/m 2 ] |
Sunload value calculated by A/C auto amp. |
|
COMP REQ SIG |
[On/Off] |
Displays A/C switch ON/OFF status transmitted to other units via CAN communication. |
|
FAN REQ SIG |
[On/Off] |
Displays front blower motor ON/OFF status transmitted to other units via CAN communication. |
|
FAN DUTY |
Duty ratio of front blower motor judged by A/C auto amp. |
|
|
XM |
Target discharge front air temperature (driver side) judged by A/C auto amp. depending on the temperature setting and the value from each sensor. |
|
|
RR XM |
Target discharge rear air temperature judged by A/C auto amp. depending on the temperature setting and the value from each sensor. |
|
|
PA TARGET A/TEMP |
Target discharge front air temperature (passenger side) judged by A/C auto amp. depending on the temperature setting and the value from each sensor. |
|
|
ENG COOL TEMP |
[ deg.C (deg.F)] |
Engine coolant temperature signal value received from ECM via CAN communication. |
|
VEHICLE SPEED |
[km/h (mph)] |
Vehicle speed signal value received from combination meter via CAN communication. |
|
GAS SENSR DETECT LEVEL |
Displays value according to contamination of ambient air. |
|
|
TRI ZONE XM |
Target discharge tri zone air temperature judged by A/C auto amp. depending on the temperature setting and the value from each sensor. |
|
|
BOOSTR FAN RQST SIGNAL |
[On/Off] |
Displays rear blower motor ON/OFF status transmitted to other units via CAN communication. |
|
BOOSTER FAN DUTY |
Duty ratio of rear blower motor judged by A/C auto amp. |
|
|
PASS SUNL CAL |
[w/m 2 ] |
Sunload value (passenger side)calculated by A/C auto amp. |
|
PASS SUNL SEN CAL |
[w/m 2 ] |
Sunload sensor value calculated from sunload sensor signal (passenger side) received from sunload sensor. |