Around View Monitor System (DTC/Circuit Diagnosis)
- CHECK CONTINUITY OF FRONT CAMERA POWER SUPPLY AND GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M97 and front camera connector E226.
- Check continuity between around view monitor control unit connector M97 and front camera connector E226.
Around view monitor control unit
Front camera
Continuity
Connector
Terminal
Connector
Terminal
M97
68
E226
1
Yes
70
2
- Check continuity between around view monitor control unit connector M97 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M97
68
No
Is the inspection result normal?
YES
GO TO 2.
NO
Repair harness or connector.
- CHECK VOLTAGE OF FRONT CAMERA POWER SUPPLY
- Connect around view monitor control unit connector M97 and front camera connector E226.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector M97.
Around view monitor control unit
Condition
Voltage
(Approx.)
Connector
(+)
(-)
Terminal
M97
68
70
"CAMERA" switch is ON or shift position is "R".
6.0 V
Is the inspection result normal?
YES
GO TO 3.
NO
Replace around view monitor control unit. Refer to Removal and Installation .
- CHECK CONTINUITY OF FRONT CAMERA IMAGE SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M97 and front camera connector E226.
- Check continuity between around view monitor control unit connector M97 and front camera connector E226.
Around view monitor control unit
Front camera
Continuity
Connector
Terminal
Connector
Terminal
M97
71
E226
3
Yes
72
4
- Check continuity between around view monitor control unit connector M97 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M97
71
No
Is the inspection result normal?
YES
GO TO 4.
NO
Repair harness or connector.
- CHECK FRONT CAMERA IMAGE SIGNAL
- Connect around view monitor control unit connector M97 and front camera connector E226.
- Turn ignition switch ON.
- Check signal between around view monitor control unit connector M97.
Around view monitor control unit
Condition
Reference value
Connector
(+)
(-)
Terminal
M97
71
72
"CAMERA" switch is ON or shift position is "R".
Is the inspection result normal?
YES
Replace around view monitor control unit. Refer to Removal and Installation .
NO
Replace front camera. Refer to Removal and Installation .