Around View Monitor System (DTC/Circuit Diagnosis)
- CHECK CONTINUITY OF SIDE CAMERA RH POWER SUPPLY AND GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M97 and door mirror RH connector D116.
- Check continuity between around view monitor control unit connector M97 and door mirror RH connector D116.
Around view monitor control unit
Door mirror RH
Continuity
Connector
Terminal
Connector
Terminal
M97
62
D116
6
Yes
64
18
- Check continuity between around view monitor control unit connector M97 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M97
62
No
Is the inspection result normal?
YES
GO TO 2.
NO
Repair harness or connector.
- CHECK VOLTAGE OF SIDE CAMERA RH POWER SUPPLY
- Connect around view monitor control unit connector M97 and door mirror RH connector D116.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector M97 and ground.
(+)
(-)
Condition
Voltage
(Approx.)
Around view monitor control unit
Connector
Terminal
M97
62
Ground
"CAMERA" switch is ON or shift position is "R".
6.0 V
Is the inspection result normal?
YES
GO TO 3.
NO
Replace around view monitor control unit. Refer to Removal and Installation .
- CHECK CONTINUITY OF SIDE CAMERA RH IMAGE SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M97 and door mirror RH connector D116.
- Check continuity between around view monitor control unit connector M97 and door mirror RH connector D116.
Around view monitor control unit
Door mirror RH
Continuity
Connector
Terminal
Connector
Terminal
M97
65
D116
5
Yes
66
17
- Check continuity between around view monitor control unit connector M97 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M97
65
No
Is the inspection result normal?
YES
GO TO 4.
NO
Repair harness or connector.
- CHECK SIDE CAMERA RH IMAGE SIGNAL
- Connect around view monitor control unit connector M97 and door mirror RH connector D116.
- Turn ignition switch ON.
- Check signal between around view monitor control unit connector M97.
Around view monitor control unit
Condition
Reference value
Connector
(+)
(-)
Terminal
M97
65
66
"CAMERA" switch is ON or shift position is "R".
Is the inspection result normal?
YES
Replace around view monitor control unit. Refer to Removal and Installation .
NO
Replace side camera RH. Refer to Removal and Installation .