Starting Combination Meter Self-Diagnosis Mode
WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
- Check combination meter power supply and ground circuits if self-diagnosis mode does not start. Refer to Diagnosis Procedure . Replace combination meter if power supply and ground circuits are found to be normal and self-diagnosis mode does not start. Refer to Removal and Installation .
- Combination meter self-diagnosis mode will function with the ignition switch in ON. Combination meter self-diagnosis mode will exit upon turning the ignition switch to OFF.
How to Initiate Self-Diagnosis Mode
- Press and hold the trip reset switch while turning the ignition switch ON. After 2 seconds release trip reset switch, then press the trip reset switch 3 times within 7 seconds after the ignition switch is turned ON.
- When the diagnosis function is activated, the meter illuminates all of the following:
- Warning lights/indicators.
- Meter assembly.
- Information display color bars red, green, blue and white (1).
- Odometer, trip A/B odometers and CVT indicator LCD display segments (2).
3. Press and hold the trip reset switch performs the pointer sweep test.