  1. CHECK COMBINATION METER INPUT SIGNAL 
    1. Select HVAC on CONSULT.
    2. Check AMB TEMP SEN of DATA MONITOR.

    Does the ambient temperature approximately match the CONSULT display?

    YES

    Replace combination meter. Refer to Removal and Installation .

    NO

    GO TO 2.

  2. CHECK AMBIENT SENSOR SIGNAL CIRCUIT 

    Check the ambient sensor signal circuit. Refer to Diagnosis Procedure .

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair or replace harness or connectors.

  3. CHECK AMBIENT SENSOR 

    Check the ambient sensor. Refer to Component Inspection .

    Is the inspection result normal?

    YES

    Replace combination meter. Refer to Removal and Installation .

    NO

    Replace ambient sensor. Refer to Removal and Installation .