Diagnosis Procedure
- CHECK MOOD LAMP POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect the BCM connector.
- Disconnect mood lamp connectors.
- Check continuity between BCM harness connector and mood lamp harness connectors.
BCM
Mood lamp
Continuity
Connector
Terminal
Connector
Terminal
M17
137
Instrument panel LH outer
M85
2
Yes
Instrument panel LH inner
M183
Instrument panel RH
M184
Front door armrest LH
D15
Front door armrest RH
D117
Is the inspection result normal?
YES
GO TO 2 .
NO
Repair or replace harnesses.
- CHECK MOOD LAMP CONTROL CIRCUIT
- Turn ignition switch ON.
- Check voltage between combination meter harness connector and ground.
(+)
(-)
Condition
Voltage
(Approx.)
Combination meter
Connector
Terminal
M23
47
Ground
Mood lamp
On
0 V
Off
Battery voltage
Is the inspection result normal?
YES
GO TO 3 .
NO
Replace combination meter. Refer to Removal and Installation .
- CHECK MOOD LAMP OPEN CIRCUIT
- Disconnect combination meter connector.
- Check continuity between combination meter harness connector and mood lamp (instrument panel LH outer/LH inner/RH), mood lamp (front door armrest LH/RH).
Mood lamp (instrument panel)Combination meter
Mood lamp (instrument panel)
Continuity
Connector
Terminal
Connector
Terminal
M23
47
LH outer
M85
3
Yes
LH inner
M183
RH
M184
Mood lamp (front door armrest)Combination meter
Mood lamp (front door armrest)
Continuity
Connector
Terminal
Connector
Terminal
M23
47
LH
D15
3
Yes
RH
D117
Is the inspection result normal?
YES
Mood lamp (instrument panel): Replace mood lamp (instrument panel). Refer to Removal and Installation .
YES
Mood lamp (front door armrest): Replace mood lamp (front door armrest). Refer to Removal and Installation .
NO
Repair or replace harnesses.