DTC Detection Logic
WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
|
DTC
|
CONSULT screen terms
(Trouble diagnosis content)
|
DTC detection condition
|
Possible cause
|
|
P0776
|
PC SOLENOID B
(Pressure Control Solenoid "B" Performance/Stuck Off)
|
When any of 1 or 2 is satisfied and this state is maintained for 10 seconds:
- When all of the following conditions are satisfied:
- DTC other than the applicable DTC is not detected.
- Engine speed: More than 625 rpm
- Selector lever: Other than P/N position
- CVT fluid temperature: More than -20 deg.C (-4 deg.F)
- TCM power supply: More than 11 V
- The difference between instruction pressure of secondary pressure and 10-msec-ago instruction secondary pressure is 0 MPa or more
- Instruction pressure of secondary pressure: 0 MPa or more
- Instruction pressure of secondary pressure - secondary pressure: More than 1.2 MPa
- When all of the following conditions are satisfied and this state is maintained for 1.52 seconds:
- DTC other than the applicable DTC is not detected.
- CVT fluid temperature: More than -20 deg.C (-4 deg.F)
- Selector lever: Other than P/N position
- Instruction pressure of secondary pressure - secondary pressure: 0.25 MPa or more
- When all of the following conditions are satisfied:
- DTC other than the applicable DTC is not detected.
- CVT fluid temperature: More than -20 deg.C (-4 deg.F)
- Selector lever: Other than P/N position
- TCM power supply: More than 11 V
- When all of the following conditions are satisfied and this state is maintained for 5.5 seconds:
- DTC other than the applicable DTC is not detected.
- CVT fluid temperature: More than -20 deg.C (-4 deg.F)
- Selector lever: Other than P/N position
- Secondary pressure - instruction pressure of secondary pressure: 1.2 MPa or more
- The difference between instruction pressure of secondary pressure and 10-msec-ago instruction secondary pressure is 0 MPa or more
- Secondary pressure - instruction pressure of secondary pressure: More than 1.2 MPa
|
- Secondary pressure solenoid valve (Control valve)
- CVT chain
|