Diagnosis Procedure
- CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120V OUTLET
- Turn ignition switch OFF.
- Disconnect inverter unit and AC 120V outlet connectors.
- Check continuity between inverter unit connector B82 terminals 5, 1 and AC 120V outlet connector M256 terminals 1, 4.
Inverter unit
AC 120V outlet
Continuity
Connector
Terminal
Connector
Terminal
B82
5
M256
1
Yes
1
4
- Check continuity between inverter unit connector B82 terminals 5, 1 and ground.
Inverter unit
Ground
Continuity
Connector
Terminal
B82
5
--
No
1
- Check continuity between inverter unit connector B82 terminals 5 and 1.
Inverter unit
Continuity
Connector
Terminal
B82
5
1
No
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace the harness or connectors.
- CHECK INVERTER UNIT OUTPUT SIGNAL
- Connect inverter unit and AC 120V outlet connectors.
- Turn ignition switch ON.
- AC 120V outlet main switch ON (AC 120V outlet main switch indicator ON).
- Check voltage between inverter unit connector B82 terminals 5 and 1.CAUTION:
- To measure AC 120V output signal, always use the circuit tester AC range.
- Never allow the probes to contact each other.
Inverter unit connector B82 terminals
Condition
Voltage
(Approx.)
(+)
(-)
AC 120V outlet main switch
5
1
OFF
0V
ON
AC 120V
Is the inspection result normal?
YES
GO TO 3.
NO
Replace inverter unit.
- CHECK AC 120V OUTLET VOLTAGE
Check voltage between AC 120V outlet M256 terminals 1 and 4.
CAUTION:- To measure AC 120V output signal, always use the circuit tester AC range.
- Never allow the probes to contact each other.
AC 120V outlet connector M256 terminals
Condition
Voltage
(Approx.)
(+)
(-)
AC 120V outlet main switch
1
4
OFF
0V
ON
AC 120V
Is the inspection result normal?
YES
GO TO 4.
NO
Replace AC 120V outlet.
- CHECK AC 120V OUTLET GROUND CIRCUIT
- AC 120V outlet main switch OFF.
- Turn ignition switch OFF.
- Disconnect AC 120V outlet connector.
- Check continuity between AC 120V outlet connector M256 terminal 3 and ground.
AC 120V outlet
Ground
Continuity
Connector
Terminal
M256
3
--
Yes
Is the inspection result normal?
YES
Replace AC 120V outlet.
NO
Repair AC 120V outlet ground circuit.