Diagnosis Procedure

WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120V OUTLET 
    1. Turn ignition switch OFF.
    2. Disconnect inverter unit and AC 120V outlet connectors.
    3. Check continuity between inverter unit connector B82 terminals 5, 1 and AC 120V outlet connector M256 terminals 1, 4.

      Inverter unit

      AC 120V outlet

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      B82

      5

      M256

      1

      Yes

      1

      4

    4. Check continuity between inverter unit connector B82 terminals 5, 1 and ground.

      Inverter unit

      Ground

      Continuity

      Connector

      Terminal

      B82

      5

      --

      No

      1

    5. Check continuity between inverter unit connector B82 terminals 5 and 1.

      Inverter unit

      Continuity

      Connector

      Terminal

      B82

      5

      1

      No

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Repair or replace the harness or connectors.

  2. CHECK INVERTER UNIT OUTPUT SIGNAL 
    1. Connect inverter unit and AC 120V outlet connectors.
    2. Turn ignition switch ON.
    3. AC 120V outlet main switch ON (AC 120V outlet main switch indicator ON).
    4. Check voltage between inverter unit connector B82 terminals 5 and 1.
      CAUTION:
      • To measure AC 120V output signal, always use the circuit tester AC range.
      • Never allow the probes to contact each other.

      Inverter unit connector B82 terminals

      Condition

      Voltage

      (Approx.)

      (+)

      (-)

      AC 120V outlet main switch

      5

      1

      OFF

      0V

      ON

      AC 120V

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Replace inverter unit.

  3. CHECK AC 120V OUTLET VOLTAGE 

    Check voltage between AC 120V outlet M256 terminals 1 and 4.

    CAUTION:
    • To measure AC 120V output signal, always use the circuit tester AC range.
    • Never allow the probes to contact each other.

    AC 120V outlet connector M256 terminals

    Condition

    Voltage

    (Approx.)

    (+)

    (-)

    AC 120V outlet main switch

    1

    4

    OFF

    0V

    ON

    AC 120V

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Replace AC 120V outlet.

  4. CHECK AC 120V OUTLET GROUND CIRCUIT 
    1. AC 120V outlet main switch OFF.
    2. Turn ignition switch OFF.
    3. Disconnect AC 120V outlet connector.
    4. Check continuity between AC 120V outlet connector M256 terminal 3 and ground.

      AC 120V outlet

      Ground

      Continuity

      Connector

      Terminal

      M256

      3

      --

      Yes

    Is the inspection result normal?

    YES

    Replace AC 120V outlet.

    NO

    Repair AC 120V outlet ground circuit.