LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 552 (Power Window Control System (DTC/Circuit Diagnosis)) >> Circuit Diagnosis >> Power Supply And Ground Circuit >> Power Window Main Switch >> DTC Diagnosis Procedure

DTC Diagnosis Procedure

WARNING: This page is about a different car, the 2019 Nissan NV3500 HD, 2019 Nissan NV2500 HD, and 2019 Nissan NV1500. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK POWER SUPPLY 
    1. Turn ignition switch ON.
    2. Check voltage between main power window and door lock/unlock switch connector D7 terminals 9, 13 and ground.

      Main power window and door lock/unlock switch

      Ground

      Voltage

      (approx.)

      Connector

      Terminal

      D7

      9

      --

      Battery voltage

      13

    Is the inspection result normal?

    YES

    GO TO 3

    NO

    GO TO 2

  2. CHECK POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect BCM connector M20 and main power window and door lock/unlock switch connector.
    3. Check continuity between BCM connector M20 terminals 68, 69 and main power window and door lock/unlock switch connector D7 terminals 13, 9.

      BCM

      Main power window and door lock/unlock switch

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      M20

      68

      D7

      13

      Yes

      69

      9

    4. Check continuity between BCM connector M20 terminals 68, 69 and ground.

      BCM

      Ground

      Continuity

      Connector

      Terminal

      M20

      68

      --

      No

      69

    Is the inspection result normal?

    YES

    Replace BCM. Refer to Removal and Installation .

    NO

    Repair or replace harness.

  3. CHECK GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect main power window and door lock/unlock switch connector.
    3. Check continuity between main power window and door lock/unlock switch connector D7 terminal 10 and ground.

      Main power window and door lock/unlock switch

      Ground

      Continuity

      Connector

      Terminal

      D7

      10

      --

      Yes

    Is the inspection result normal?

    YES

    Inspection End.

    NO

    Repair or replace harness.