Component Inspection
- CHECK FUNCTION
- Select CR SEN[FL], CR SEN[FR], CTR SEN [FL], CTR SEN [FR], CR SEN[RL], CR SEN[RR], CTR SEN [RL], CTR SEN [RR] in Data monitor mode with CONSULT.
- Check sonar sensor signal under the following conditions.
Monitor Item
Display
Description
CR SEN[FL]
CR SEN[FR]
CR SEN[RL]
CR SEN[RR]
ERROR
ERROR is displayed under the following conditions:
- sensor is malfunctioning.
- sensor is disconnected.
- sensor circuit is open.
LV.0
When a sensor is not detecting an object
LV.1
The distance between the corner sensor and an obstacle is 100 cm (36 in.) or more and less then 180 cm (70.92 in.).
LV.2
The distance between the corner sensor and an obstacle is 70 cm (27.6 in.) or more and less then 100 cm (36 in.).
LV.3
The distance between the corner sensor and an obstacle is 50 cm (19.6 in.) or more and less then 70 cm (27.6 in.).
LV.4
The distance between corner sensor and an obstacle less than 50 cm (19.6 in.).
CTR SEN [RL]
CTR SEN [RR]
CTR SEN [FL]
CTR SEN [FR]
ERROR
ERROR is displayed under the following conditions:
- sensor is malfunctioning.
- sensor is disconnected.
- sensor circuit is open.
LV.0
When a sensor is not detecting an object
LV.1
The distance between the center sensor and an obstacle is 60 cm (23.6in) or more and less then 100 cm (39.3 in).
LV.2
The distance between the center sensor and an obstacle is 50 cm (19.6 in) or more and less then 60 cm (23.6 in).
LV.3
The distance between the center sensor and an obstacle is 30 cm (11.8 in) or more and less then 50 cm (19.6 in).
LV.4
The distance between center sensor and an obstacle less than 30 cm (11.8 in).
Is the inspection result normal?
YES
Inspection End.
NO
Perform diagnosis procedure. Refer to Diagnosis Procedure .