DTC Diagnosis Procedure
- CHECK INPUT 1 - 5 CIRCUIT FOR OPEN
- Turn ignition switch OFF.
- Disconnect BCM, combination switch, lighting switch and front fog lamps switch connectors.
- Check continuity between BCM connector and combination switch connector.
Signal
BCM
Combination switch
Continuity
Connector
Terminal
Connector
Terminal
Input 1
M18
36
M28
11
Yes
Input 2
35
9
Input 3
34
7
Input 4
33
10
Input 5
32
13
- Check continuity between BCM connector and lighting switch connector.
Signal
BCM
Lighting switch
Continuity
Connector
Terminal
Connector
Terminal
Input 2
M18
35
M34
2
Yes
Input 3
34
3
Input 4
33
4
- Check continuity between BCM connector and front fog lamps switch connector.
Signal
BCM
Front fog lamps switch
Continuity
Connector
Terminal
Connector
Terminal
Input 5
M18
32
M10
1
Yes
Is the inspection result normal?
YES
GO TO 2.
NO
Repair harnesses or connectors.
- CHECK INPUT 1 - 5 CIRCUIT FOR SHORT
Check for continuity between BCM connector and ground.
Signal
BCM
Ground
Continuity
Connector
Terminal
Input 1
M18
36
No
Input 2
35
Input 3
34
Input 4
33
Input 5
32
Is the inspection result normal?
YES
GO TO 3.
NO
Repair harnesses or connectors.
- CHECK BCM OUTPUT VOLTAGE
- Connect BCM connector.
- Check voltage between BCM connector and ground.
Signal
Terminals
Voltage
(Approx.)
(+)
(-)
BCM
Ground
Connector
Terminal
Input 1
M18
36
Refer to Reference Value .
Input 2
35
Input 3
34
Input 4
33
Input 5
32
Is the inspection result normal?
YES
Replace malfunctioning switch.
NO
Replace BCM. Refer to Removal and Installation .