Component Description
Front air control.
The front air control has a built-in microcomputer that processes information sent from various sensors needed for air conditioner operation. The air mix door motor, the mode door motor, the intake door motor, the blower motor and the A/C compressor are then controlled.
- CHECK FRONT AIR CONTROL POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect the front air control connector.
- Turn ignition switch ON.
- Check voltage between front air control harness connector M53 terminals 1, 2 and ground.
(+)
(-)
Voltage
Front air control
--
Ignition switch position
Connector
Terminal
OFF
ACC
ON
M53
1
Ground
Battery voltage
Battery voltage
Battery voltage
2
Approx. 0 V
Approx. 0 V
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK FUSE
Check 10 A fuses [Nos. 12 and 19, located in the fuse block (J/B)].
NOTE: Refer to appropriate system Wiring Diagram.Is the inspection result normal?
YES
Check harness for open circuit. Repair or replace if necessary.
NO
Check harness for short circuit. Repair or replace if necessary.
- CHECK FRONT AIR CONTROL GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between front air control harness connector M53 terminals 3, 4 and ground.
3, 4 - Ground
: Continuity should exist.
Is the inspection result normal?
YES
Replace the front air control. Refer to Removal and Installation - Front Air Control .
NO
Repair the harnesses or connectors.