Diagnosis Procedure
- CHECK POWER SUPPLY
Check if the following fuse in the fuse block (J/B) is blown.
Component
Capacity
Fuse No.
Fuse block (J/B)
10 A
22
Is the inspection result normal?
YES
GO TO 2 .
NO
Replace the blown fuse after repairing the affected circuit.
- CHECK DOOR MIRROR DEFOGGER POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect door mirror RH.
- Turn ignition switch ON.
- Check voltage between door mirror RH connector and ground.
(+)
(-)
Condition
Voltage (V)
(Approx.)
Door mirror RH
Connector
Terminal
D107
1
Ground
Rear window defogger switch
ON
Battery voltage
OFF
0
Is the inspection result normal?
YES
GO TO 3
NO
Repair or replace harness.
- CHECK DOOR MIRROR DEFOGGER GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between door mirror RH connector and ground.
Door mirror RH
Ground
Continuity
Connector
Terminal
D107
5
Yes
Is the inspection result normal?
YES
GO TO 4 .
NO
Repair or replace harness.
- CHECK DOOR MIRROR DEFOGGER RH
Check door mirror defogger RH. Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 5 .
NO
Replace door mirror. Refer to Removal and Installation .
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to Intermittent Incident .
Is the inspection result normal?
YES
Check the following:
- Battery power supply circuit
- Fuse block (J/B)
NO
Repair or replace the malfunctioning parts.