DTC Diagnosis Procedure
Receives keyfob operation and transmits to BCM.
- CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
- Turn ignition switch OFF.
- Check signal between BCM harness connector and ground using oscilloscope.
Terminals
Condition
Signal
(Reference value)
(+)
(-)
BCM
Terminal
M18
20
Ground
Waiting
(All doors closed)
When signal is received
(All doors closed)
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
GO TO 2
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY
- Disconnect remote keyless entry receiver connector.
- Check signal between remote keyless entry receiver connector and ground with oscilloscope.
Terminals
Signal
(Reference value)
(+)
(-)
Remote keyless entry receiver connector
Terminal
M120
4
Ground
Is the inspection result normal?
YES
GO TO 4
NO
GO TO 3
- CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 1
- Disconnect BCM connector.
- Check continuity between BCM connector and remote keyless entry receiver connector.
BCM connector
Terminal
Remote keyless entry receiver
connector
Terminal
Continuity
M18
19
M120
4
Yes
- Check continuity between BCM connector and ground.
BCM connector
Terminal
Ground
Continuity
M18
19
No
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness between BCM and remote keyless entry receiver.
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
Check continuity between remote keyless entry receiver connector and ground.
Remote keyless entry receiver
connector
Terminal
Ground
Continuity
M120
1
Yes
Is the inspection result normal?
YES
GO TO 6
NO
GO TO 5
- CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 2
Check continuity between BCM connector and remote keyless entry receiver connector.
BCM
connector
Terminal
Remote keyless entry receiver
connector
Terminal
Continuity
M18
18
M120
1
Yes
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness between BCM and remote keyless entry receiver.
- CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 3
- Check continuity between BCM connector and remote keyless entry receiver connector.
BCM
connector
Terminal
Remote keyless entry receiver
connector
Terminal
Continuity
M18
20
M120
2
Yes
- Check continuity between BCM connector and ground.
BCM connector
Terminal
Ground
Continuity
M18
20
No
Is the inspection result normal?
YES
Replace remote keyless entry receiver. Refer to Removal and Installation .
NO
Repair or replace harness between BCM and remote keyless entry.
- Check continuity between BCM connector and remote keyless entry receiver connector.