DTC Diagnosis Procedure
- CHECK TCM INPUT SIGNAL
- Turn ignition switch ON.
- Select "TOW MODE SWITCH" in "Data Monitor" in "TRANSMISSION".
- Check the ON/OFF operations of each monitor item.
Monitor Item
Condition
Status
TOW MODE SWITCH
TOW mode switch: Pushed
ON
Other than the above
OFF
Is the inspection result normal?
YES
Check intermittent incident. Refer to Intermittent Incident .
NO
GO TO 2.
- CHECK CIRCUIT BETWEEN COMBINATION METER AND A/T SHIFT SELECTOR
- Turn ignition switch OFF.
- Disconnect combination meter connector and A/T shift selector connector.
- Check continuity between A/T shift selector harness connector terminals and combination meter harness connector terminals.
A/T shift selector
Combination meter
Continuity
Connector
Terminal
Connector
Terminal
M68
6
M24
10
Existed
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace malfunctioning parts.
- CHECK CIRCUIT BETWEEN COMBINATION METER AND A/T SHIFT SELECTOR
Check continuity between combination meter harness connector terminals and ground.
Combination meter
--
Continuity
Connector
Terminal
M24
10
Ground
Not existed
Is the inspection result normal?
YES
GO TO 4.
NO
Repair or replace malfunctioning parts.
- CHECK A/T SHIFT SELECTOR GROUND CIRCUIT
Check continuity between A/T shift selector connector harness connector terminals and ground.
A/T shift selector
--
Continuity
Connector
Terminal
M68
2
Ground
Existed
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace malfunctioning parts.
- CHECK COMBINATION METER
Check combination meter. Refer to Work Flow .
Is the inspection result normal?
YES
Replace the A/T shift selector. Refer to Removal and Installation .
NO
Replace the combination meter. Refer to Removal and Installation .