LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 510 (Manual Air Conditioner (DTC/Circuit Diagnosis)) >> DTC/Circuit Diagnosis >> Rear Blower Motor >> DTC Diagnosis Procedure

DTC Diagnosis Procedure

WARNING: This page is about a different car, the 2019 Nissan NV3500 HD, 2019 Nissan NV2500 HD, and 2019 Nissan NV1500. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK FUSE 
    1. Turn ignition switch OFF.
    2. Check 30 A fuse (No. 57).
      NOTE: Refer to appropriate system Wiring Diagram.

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Replace the blown fuse after repairing the affected circuit if a fuse is blown.

  2. CHECK REAR BLOWER MOTOR POWER SUPPLY 
    1. Disconnect rear blower motor connector.
    2. Turn ignition switch ON.
    3. Check voltage between rear blower motor harness connector and ground.

      +

      -

      Voltage

      (Approx.)

      Rear blower motor

      Connector

      Terminal

      B21

      1

      Ground

      Battery voltage

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    GO TO 6.

  3. CHECK REAR BLOWER MOTOR GROUND CIRCUIT FOR OPEN 
    1. Turn ignition switch OFF.
    2. Check continuity between rear blower motor harness connector and ground.

      Rear blower motor

      --

      Continuity

      Connector

      Terminal

      B21

      3

      Ground

      Yes

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair harness or connector.

  4. CHECK REAR BLOWER MOTOR CONTROL SIGNAL CIRCUIT FOR OPEN 
    1. Disconnect front air control connector.
    2. Check continuity between rear blower motor harness connector and front air control connector.

      Rear blower motor

      Front air control

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      B21

      2

      M51

      33

      Yes

    Is the inspection result normal?

    YES

    GO TO 5.

    NO

    Repair harness or connector.

  5. CHECK REAR BLOWER MOTOR CONTROL SIGNAL 
    1. Reconnect rear blower motor connector and front air control connector.
    2. Turn ignition switch ON.
    3. Change rear fan speed from Lo to Hi, and check duty ratios between rear blower motor harness connector and ground by using an oscilloscope.
      NOTE: Calculate drive signal duty ratio as shown in the figure, below.

      T2 = Approx. 1.6 ms

      G00516006Courtesy of NISSAN NORTH AMERICA, INC.

      Rear blower motor

      Condition

      Duty ratio

      (Approx.)

      Connector

      Terminal

      Fan speed

      B21

      2

      1st

      25 %

      2nd

      33 %

      3rd

      41 %

      4th

      51 %

      5th

      61 %

      6th

      69 %

      7th

      81 %

    Is the inspection result normal?

    YES

    Replace rear blower motor. Refer to Removal and Installation - Rear Blower Motor (If Equipped) .

    NO

    Replace front air control. Refer to Removal and Installation - Front Air Control .

  6. CHECK REAR BLOWER MOTOR POWER SUPPLY CIRCUIT FOR OPEN 
    1. Turn ignition switch OFF.
    2. Disconnect rear blower motor relay connector.
    3. Check continuity between rear blower motor relay harness connector and rear blower motor harness connector.

      Rear blower motor relay

      Rear blower motor

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      M59

      3

      B21

      1

      Yes

      6

    Is the inspection result normal?

    YES

    GO TO 7.

    NO

    Repair harness or connector.

  7. CHECK REAR BLOWER MOTOR RELAY GROUND CIRCUIT FOR OPEN 

    Check continuity between rear blower motor relay harness connector and ground.

    Rear blower motor relay

    --

    Continuity

    Connector

    Terminal

    M59

    1

    Ground

    Yes

    Is the inspection result normal?

    YES

    GO TO 8.

    NO

    Repair harness or connector.

  8. CHECK REAR BLOWER MOTOR RELAY 

    Check rear blower motor relay. Refer to Component Inspection (Rear Blower Motor Relay) .

    Is the inspection result normal?

    YES

    Check rear blower motor relay power supply circuit. Refer to appropriate system Wiring Diagram (Battery Power Supply) and (Ignition Power Supply).

    NO

    Replace rear blower motor relay.