Circuit Diagnosis Procedure
Terminal "1" (B) is constantly supplied with battery power.
- Remove fuel pump fuse.
- Crank or start the engine (where possible) until the fuel pressure is depleted.
- CHECK TERMINAL 1 POWER SUPPLY VOLTAGE
- Turn ignition switch OFF.
- Make sure that starter motor connector E208 (VQ40DE) or F27 (VK56VD) terminal 1 connection is clean and tight.
- Check voltage between starter motor connector E208 (VQ40DE) or F27 (VK56VD) terminal 1 and ground.
(+)
(-)
Voltage
Connector
Terminal
E208 (VQ40DE)
1
Ground
Battery voltage
F27 (VK56VD)
Is the inspection result normal?
YES
GO TO 2
NO
Check harness between battery and starter motor for open circuit.
- CHECK BATTERY CABLE (VOLTAGE DROP TEST)
- Shift the transmission into P (Park) or N (Neutral).
- Check voltage between battery positive terminal and starter motor connector E208 (VQ40DE) or F27 (VK56VD) terminal 1 while cranking the engine.
(+)
(-)
Condition
Voltage
Connector
Terminal
E208 (VQ40DE)
1
Battery (+) terminal
While cranking the engine
Less than 0.2 V
F27 (VK56VD)
Is the inspection result normal?
YES
GO TO 3
NO
Check harness between the battery and the starter motor for high resistance.
- CHECK GROUND CIRCUIT STATUS (VOLTAGE DROP TEST)
Check voltage between starter motor case and battery negative terminal while cranking the engine.
(+)
(-)
Condition
Voltage
Starter motor case
Battery (-) terminal
While cranking the engine
Less than 0.2 V
Is the inspection result normal?
YES
Terminal 1 circuit is OK. Further inspection is necessary. Refer to Work Flow (With DSS-5000P NI) or Work Flow (Without DSS-5000P NI) .
NO
Check the starter motor case to engine mounting for high resistance.