Diagnosis Procedure
Performs trunk lid open request when it is pressed.
- CHECK TRUNK OPENER REQUEST SWITCH OUTPUT SIGNAL
- Turn ignition switch OFF.
- Check voltage between BCM connector and ground.
Terminal
Trunk lid opener request switch condition
Voltage (V)
(Approx.)
(+)
(-)
BCM
Terminal
M19
83
Ground
Pressed
0
Released
Battery voltage
Is the inspection result normal?
YES
GO TO 6 .
NO
GO TO 2 .
- CHECK TRUNK OPENER REQUEST SWITCH CIRCUIT
- Disconnect BCM and trunk opener request switch connector.
- Check continuity between BCM connector and trunk opener request switch connector.
BCM
Terminal
Trunk opener request switch
Terminal
Continuity
M19
83
B25
1
Yes
- Check continuity between BCM connector and ground.
BCM
Terminal
Ground
Continuity
M19
83
No
Is the inspection result normal?
YES
GO TO 3 .
NO
Repair or replace harness between BCM and trunk opener request switch.
- CHECK TRUNK OPENER REQUEST SWITCH GROUND CIRCUIT
Check continuity between trunk opener request switch connector and ground.
Trunk opener request switch
Terminal
Ground
Continuity
B25
2
Yes
Is the inspection result normal?
YES
GO TO 4 .
NO
Repair or replace trunk opener request switch ground circuit.
- CHECK BCM OUTPUT SIGNAL
- Connect BCM connector.
- Check voltage between BCM connector and ground.
Terminal
Voltage (V)
(Approx.)
(+)
(-)
BCM
Terminal
M19
83
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 5 .
NO
Replace BCM. Refer to Removal and Installation .
- CHECK TRUNK OPENER REQUEST SWITCH
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 6 .
NO
Replace trunk opener request switch.
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
Inspection End.