Diagnosis Procedure
Performs trunk lid open with signal from BCM.
- CHECK OUTPUT CIRCUIT
- Turn ignition switch OFF.
- Disconnect trunk lamp switch and trunk release solenoid assembly connector.
- Check voltage between trunk lamp switch and trunk release solenoid assembly connector and ground.
Terminal
Condition of trunk lid opener switch
Voltage (V)
(Approx.)
(+)
(-)
Trunk lamp switch and trunk release solenoid assembly
Terminal
B43
3
Ground
OFF → ON
0 → Battery voltage → 0
Is the inspection result normal?
YES
GO TO 4
NO
GO TO 2 .
- CHECK OUTPUT SIGNAL
Check voltage between BCM connector and ground.
Terminal
Condition of trunk lid opener switch
Voltage (V)
(Approx.)
(+)
(-)
BCM
Terminal
M19
91
Ground
OFF → ON
0 → Battery voltage → 0
Is the inspection result normal?
YES
Repair or replace harness.
NO
GO TO 3 .
- CHECK TRUNK LID OPENER ACTUATOR CIRCUIT
- Disconnect BCM.
- Check continuity between BCM connector and trunk lamp switch and trunk release solenoid assembly connector.
BCM
Terminal
Trunk lamp switch and trunk release solenoid assembly
Terminal
Continuity
M19
91
B43
3
Yes
- Check continuity between BCM connector and ground.
BCM
Terminal
Continuity
M19
91
Ground
No
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK TRUNK LID OPENER GROUND CIRCUIT
Check continuity between trunk lamp switch and trunk release solenoid assembly connector and ground.
Trunk lamp switch and trunk release solenoid assembly
Terminal
Continuity
B43
2
Ground
Yes
Is the inspection result normal?
YES
Replace trunk lamp switch and trunk release solenoid assembly.
NO
Repair or replace harness.