LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 5 (Power Door Lock System (DTC/Circuit Diagnosis)) >> DTC/Circuit Diagnosis >> Trunk Lamp Switch >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2018 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.

Detects trunk open/close condition.

  1. CHECK TRUNK LAMP SWITCH INPUT SIGNAL 
    1. Turn ignition switch OFF.
    2. Check voltage between BCM connector and ground.

      Terminal

      Trunk

      condition

      Voltage (V)

      (Approx.)

      (+)

      (-)

      BCM

      connector

      Terminal

      M19

      97

      Ground

      OPEN

      0

      CLOSE

      G06991539Courtesy of NISSAN NORTH AMERICA, INC.

    Is the inspection result normal?

    YES

    GO TO 6 .

    NO

    GO TO 2 .

  2. CHECK TRUNK LAMP SWITCH CIRCUIT 
    1. Disconnect BCM and trunk lamp switch and trunk release solenoid connectors.
    2. Check continuity between BCM connector and trunk lamp switch and trunk release solenoid assembly connector.

      BCM connector

      Terminal

      Trunk lamp switch and trunk release solenoid assembly connector

      Terminal

      Continuity

      M19

      97

      B43

      1

      Yes

    3. Check continuity between BCM connector and ground.

      BCM connector

      Terminal

      Ground

      Continuity

      M19

      97

      No

    Is the inspection result normal?

    YES

    GO TO 3 .

    NO

    Repair or replace harness between BCM and trunk lamp switch and trunk release solenoid assembly.

  3. CHECK TRUNK LAMP SWITCH GROUND CIRCUIT 

    Check continuity between trunk lamp switch and trunk release solenoid assembly connector and ground.

    Trunk lamp switch and trunk release solenoid assembly connector

    Terminal

    Ground

    Continuity

    B43

    2

    Yes

    Is the inspection result normal?

    YES

    GO TO 4 .

    NO

    Repair or replace trunk lamp switch and trunk release solenoid assembly ground circuit.

  4. CHECK BCM OUTPUT SIGNAL 
    1. Insure trunk remains closed during this step.
    2. Connect BCM connector.
    3. Check voltage between BCM connector and ground.

      Terminals

      Voltage (V)

      (Approx.)

      (+)

      (-)

      BCM connector

      Terminal

      M19

      97

      Ground

      G06991539Courtesy of NISSAN NORTH AMERICA, INC.

    Is the inspection result normal?

    YES

    GO TO 5 .

    NO

    Replace BCM. Refer to Removal and Installation .

  5. CHECK TRUNK LAMP SWITCH 

    Refer to Component Inspection .

    Is the inspection result normal?

    YES

    GO TO 6 .

    NO

    Replace trunk lamp switch and trunk release solenoid assembly.

  6. CHECK INTERMITTENT INCIDENT 

    Refer to Intermittent Incident .

    Inspection End.