Inspection Procedure
- CHECK BATTERY TERMINALS CONNECTION
Check if battery terminals are clean and tight.
Is the inspection result normal?
YES
GO TO 2.
NO
Repair battery terminals connection.
- CHECK FUSE
Check for blown fuse and fusible link.
Unit
Power source (Power supply terminals)
Fuse or Fusible Link
Generator
Battery (terminal 3)
Fuse 26
Battery (terminal 1)
Fusible Link A
Combination meter
Ignition switch ON (terminal 2)
Fuse 12
Is the fuse or fusible link blown?
YES
Replace the blown fuse or fusible link after repairing the affected circuit.
NO
GO TO 3.
- CHECK GENERATOR GROUND TERMINAL CONNECTION
Verify connector E206 (VQ40DE) or E215 (VK56VD) terminal 5 (generator ground harness) is clean and tight.
Is the inspection result normal?
YES
GO TO 4.
NO
Repair connection.
- CHECK DRIVE BELT TENSION
Check drive belt tension. Refer to Checking Drive Belts (VQ40DE) or Checking (VK56VD).
Is the inspection result normal?
YES
Inspection End.
NO
Repair as needed.