DTC Diagnosis Procedure
- CHECK FUSE
Check that the following fuses of the AV control unit are not blown:
Unit
Terminals
Signal name
Fuse No.
AV control unit
19
Battery power
17 (15 A)
7
Ignition switch ACC or ON
9 (10 A)
37
Ignition switch ON or START
12 (10 A)
Are the fuses OK?
YES
GO TO 2
NO
Replace the fuse after repairing the affected circuit. Refer to Circuit Inspection .
- AV CONTROL UNIT POWER SUPPLY CIRCUIT CHECK
- Disconnect AV control unit connector.
- Check voltage between the AV control unit connectors and ground.
Unit
Terminal No.
Ignition switch position
(+)
(-)
OFF
ACC
ON
Connector
Terminal
AV control unit
M44
19
Ground
Battery voltage
Battery voltage
Battery voltage
7
Ground
0 V
Battery voltage
Battery voltage
M46
37
Ground
0 V
0 V
Battery voltage
Are the voltage results as specified?
YES
GO TO 3
NO
Check harness between AV control unit and fuse.
- CHECK GROUND CIRCUIT
- Check continuity between AV control unit harness connector M44 and ground.
(+)
(-)
Continuity
Connector
Terminal
M44
20
Ground
Yes
Does continuity exist?
YES
Inspection End.
NO
Repair harness or connector.
- Check continuity between AV control unit harness connector M44 and ground.