Diagnosis Procedure
- CHECK CIRCUIT BETWEEN TCM AND CVT UNIT
- Turn ignition switch OFF.
- Disconnect TCM connector and CVT unit connector.
- Check continuity between TCM harness connector terminal and ground.
TCM
-
Continuity
Connector
Terminal
F89
38
Ground
Not existed
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace malfunctioning parts.
- CHECK TORQUE CONVERTER CLUTCH SOLENOID VALVE CIRCUIT
Check resistance between CVT unit harness connector terminal and ground.
CVT unit
-
Condition
Resistance
Connector
Terminal
F209
5
Ground
CVT fluid temperature: 20°C (68°F)
5.5 - 7.0 ?
CVT fluid temperature: 50°C (122°F)
6.0 - 8.0 ?
CVT fluid temperature: 80°C (176°F)
6.5 - 8.5 ?
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO STEP 3 .
- CHECK CIRCUIT BETWEEN CVT UNIT AND CONTROL VALVE
- Disconnect control valve connector. Refer to Removal and Installation .
- Check continuity between CVT unit harness connector terminal and control valve harness connector terminal.
CVT unit
Control valve
Continuity
Connector
Terminal
Connector
Terminal
F209
5
F207
3
Existed
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Replace terminal code assembly. Refer to Removal and Installation .
- CHECK CIRCUIT BETWEEN CONTROL VALVE AND GROUND
Check resistance between control valve harness connector terminal and ground.
Control valve
-
Condition
Resistance
Terminal
3
Ground
CVT fluid temperature: 20°C (68°F)
5.5 - 7.0 ?
CVT fluid temperature: 50°C (122°F)
6.0 - 8.0 ?
CVT fluid temperature: 80°C (176°F)
6.5 - 8.5 ?
Is the inspection result normal?
YES
INSPECTION END
NO
There is malfunction of torque converter clutch solenoid valve circuit. Replace the control valve assembly. Refer to Removal and Installation .