Diagnosis Procedure
- CHECK CONTINUITY OF SIDE CAMERA LH POWER SUPPLY AND GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M170 and door mirror LH connector D12.
- Check continuity between around view monitor control unit connector M170 and door mirror LH connector D12.
Around view monitor control unit
Door mirror LH
Continuity
Connector
Terminal
Connector
Terminal
M170
13
D12
16
Yes
14
19
- Check continuity between around view monitor control unit harness connector M170 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M170
14
No
Is the inspection result normal?
YES
GO TO 2 .
NO
Repair harness or connector.
- CHECK VOLTAGE OF SIDE CAMERA LH POWER SUPPLY
- Connect around view monitor control unit connector M170 and door mirror LH connector D12.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector M170 and ground.
Around view monitor control unit
Condition
Voltage
(Approx.)
Connector
(+)
(-)
Terminal
M170
14
13
"CAMERA" switch is ON or shift position is "R".
6.0 V
Is the inspection result normal?
YES
GO TO 3 .
NO
Replace around view monitor control unit. Refer to Removal and Installation .
- CHECK CONTINUITY OF SIDE CAMERA LH IMAGE SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M170 and door mirror LH connector D12.
- Check continuity between around view monitor control unit connector M170 and door mirror LH connector D12.
Around view monitor control unit
Door mirror LH
Continuity
Connector
Terminal
Connector
Terminal
M170
15
D12
18
Yes
16
17
- Check continuity between around view monitor control unit connector M170 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminals
M170
16
No
Is the inspection result normal?
YES
GO TO 4 .
NO
Repair harness or connector.
- CHECK SIDE CAMERA LH IMAGE SIGNAL
- Connect around view monitor control unit connector M170 and door mirror LH connector D12.
- Turn ignition switch ON.
- Check signal between around view monitor control unit connector M170.
Around view monitor control unit
Condition
Reference value
Connector
(+)
(-)
Terminal
M170
16
15
"CAMERA" switch is ON or shift position is "R".
Is the inspection result normal?
YES
Replace around view monitor control unit. Refer to Removal and Installation .
NO
Replace side camera LH. Refer to Removal and Installation .