Diagnosis Procedure
- CHECK CONTINUITY OF SIDE CAMERA RH POWER SUPPLY AND GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M170 and door mirror RH connector D114.
- Check continuity between around view monitor control unit connector M170 and door mirror RH connector D114.
Around view monitor control unit
Door mirror RH
Continuity
Connector
Terminal
Connector
Terminal
M170
9
D114
16
Yes
10
19
- Check continuity between around view monitor control unit connector M170 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M170
10
No
Is the inspection result normal?
YES
GO TO 2 .
NO
Repair harness or connector.
- CHECK VOLTAGE OF SIDE CAMERA RH POWER SUPPLY
- Connect around view monitor control unit connector M170 and door mirror RH connector D114.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector M170 and ground.
(+)
(-)
Condition
Voltage
(Approx.)
Around view monitor control unit
Connector
Terminal
M170
10
Ground
"CAMERA" switch is ON or shift position is "R".
6.0 V
Is the inspection result normal?
YES
GO TO 3 .
NO
Replace around view monitor control unit. Refer to Removal and Installation .
- CHECK CONTINUITY OF SIDE CAMERA RH IMAGE SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector M170 and door mirror RH connector D114.
- Check continuity between around view monitor control unit connector M170 and door mirror RH connector D114.
Around view monitor control unit
Door mirror RH
Continuity
Connector
Terminal
Connector
Terminal
M170
11
D114
18
Yes
12
17
- Check continuity between around view monitor control unit connector M170 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M170
12
No
Is the inspection result normal?
YES
GO TO 4 .
NO
Repair harness or connector.
- CHECK SIDE CAMERA RH IMAGE SIGNAL
- Connect around view monitor control unit connector M170 and door mirror RH connector D114.
- Turn ignition switch ON.
- Check signal between around view monitor control unit connector M170.
Around view monitor control unit
Condition
Reference value
Connector
(+)
(-)
Terminal
M170
12
11
"CAMERA" switch is ON or shift position is "R".
Is the inspection result normal?
YES
Replace around view monitor control unit. Refer to Removal and Installation .
NO
Replace side camera RH. Refer to Removal and Installation .