LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 358 (Engine Control System (DTC/Circuit Diagnosis) (12 Of 17)) >> DTC/Circuit Diagnosis >> DTC P1801: VIAS Control Solenoid Valve 2 >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2019 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK VIAS CONTROL SOLENOID VALVE 2 POWER SUPPLY 
    1. Turn ignition switch OFF.
    2. Disconnect VIAS control solenoid valve 2 harness connector.
    3. Turn ignition switch ON.
    4. Check the voltage between VIAS control solenoid valve 2 harness connector and ground.

      +

      -

      Voltage

      VIAS control solenoid valve 2

      Connector

      Terminal

      F67

      1

      Ground

      Battery voltage

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    GO TO 2.

  2. CHECK VIAS CONTROL SOLENOID VALVE 2 POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect IPDM E/R harness connector.
    3. Check the continuity between VIAS control solenoid valve 2 harness connector and IPDM E/R harness connector.

      VIAS control solenoid valve 2

      IPDM E/R

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      F67

      1

      E121

      13

      Existed

    4. Also check harness for short to ground.

    Is the inspection result normal?

    YES

    Perform the trouble diagnosis for power supply circuit.

    NO

    Repair or replace error-detected parts.

  3. CHECK VIAS CONTROL SOLENOID VALVE 2 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between VIAS control solenoid valve 2 harness connector and ECM harness connector.

      VIAS control solenoid valve 2

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      F67

      2

      F79

      135

      Existed

    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair open circuit, short to ground or short to power in harness or connectors.

  4. CHECK VIAS CONTROL SOLENOID VALVE 2 

    Check VIAS control solenoid valve 2. Refer to Component Inspection .

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Replace VIAS control solenoid valve 2. Refer to VALVE TIMING CONTROL .