Diagnosis Procedure
- INSPECTION START
Confirm the malfunctioning system (power valve 1 or power valve 2). Refer to Component Function Check .
Which system is related to the incident?
Power valve 1
GO TO 2.
Power valve 2
GO TO 6.
- CHECK VACUUM EXISTENCE-I
With CONSULT
- Stop engine and disconnect vacuum hose connected to power valve actuator 1.
- Start engine and let it idle.
- Perform "VIAS S/V-1" in "Active Test" mode of "ENGINE" with CONSULT.
- Turn VIAS control solenoid valve 1 ON and OFF, and check vacuum existence under the following conditions.
VIAS S/V-1
Vacuum
ON
Existed
OFF
Not existed
Without CONSULT
- Stop engine and disconnect vacuum hose connected to power valve actuator 1.
- Disconnect VIAS control solenoid valve 1 harness connector.
- Start engine.
- Rev engine quickly up to approximately 5, 00 rpm.
- Check vacuum existence under the following conditions.
Condition
Vacuum
Idle
Existed
Rev engine quickly up to approximately 5, 00 rpm
Not existed
Is the inspection result normal?
YES
Repair or replace power valve actuator 1. Refer to Component Parts Location .
NO
GO TO 3.
- CHECK VACUUM TANK
- Stop engine and disconnect vacuum hose connected to intake manifold collector.
- Start engine and let it idle.
- Check vacuum existence from intake manifold collector.
Does vacuum existence from the intake manifold collector?
YES
GO TO 4.
NO
Replace intake manifold collector. Refer to INTAKE MANIFOLD COLLECTOR .
- CHECK VACUUM HOSE
- Stop engine.
- Check vacuum hose for crack, clogging, improper connection or disconnection. Refer to System Description
.
Is the inspection result normal?
YES
GO TO 5.
NO
Repair hoses or tubes.
- CHECK VIAS CONTROL SOLENOID VALVE 1
Check VIAS control solenoid valve 1. Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 8.
NO
Replace VIAS control solenoid valve 1. Refer to Component Parts Location .
- CHECK VACUUM EXISTENCE-II
With CONSULT
- Stop engine and disconnect vacuum hose connected to power valve actuator 2.
- Start engine and let it idle.
- Perform "VIAS S/V-2" in "Active Test" mode of "ENGINE" with CONSULT.
- Turn VIAS control solenoid valve 2 ON and OFF, and check vacuum existence under the following conditions.
VIAS S/V 2
Vacuum
ON
Existed
OFF
Not existed
Without CONSULT
- Stop engine and disconnect vacuum hose connected to power valve actuator 2.
- Disconnect VIAS control solenoid valve 1 harness connector.
- Start engine.
- Rev engine quickly up to approximately 5, 00 rpm.
- Check vacuum existence under the following conditions.
Condition
Operation
Idle
Existed
Rev engine quickly up to approximately 5, 00 rpm
Not existed
Is the inspection result normal?
YES
Repair or replace power valve actuator 2. Refer to Component Parts Location .
NO
GO TO 7.
- CHECK VACUUM HOSE
- Stop engine.
- Check vacuum hose for crack, clogging, improper connection or disconnection. Refer to System Description
.
Is the inspection result normal?
YES
GO TO 8.
NO
Repair hoses or tubes.
- CHECK VIAS CONTROL SOLENOID VALVE 2
Check VIAS control solenoid valve 2. Refer to Component Inspection .
Is the inspection result normal?
YES
Check intermittent incident. Refer to Intermittent Incident .
NO
Replace VIAS control solenoid valve 2. Refer to Component Parts Location .